The MTMB series wireless gas meter is a kind of household gas meter with dual synchronous display of mechanical counter and electrilcal counter. The product can be equipped with IC card valve module to achieve the intelligent gas meter with IC card .The wireless gas meter has beautiful shape, accurate measurement, easy to reading,can achieve prepayment management. It is the most ideal household gas meter.This product is also the main instrument to realize the automation and scientific management of gas supply for City Gas Company
The product can achieve the reading gas usage by in-hand wireless meter instrument without indoor.(Single or Muti gas meters). The product can form a wireless network with the GPRS concentrator, and achieve the functions of remote reading gas volumn, closing valve, recharge, and price adjustment, etc. The intelligent control device has the advantages of anti dismantling and diamagnetic interference. Mechanical counter and electrilcal counter can double display gas usage. Voice alarm alert function, when low voltage and few gas left, buzzing alarm to remind users when needed. Can directly connect with the gas leakage alarm, and use the built-in motor valve to cut off the gas supply.
规格型号
YG1.6
YG2.5
YG4.0
指标项
性 能 指 标
最大流量qmax (m3/h)
2.5
4.0
6.0
最小流量qmin (m3/h)
0.016
0.025
0.04
最大允
许误差
qt≤q≤qmax
±1.5%
qmin≤q<qt
±3%
精度等级
1.5
最大工作压力Pmax
10kPa(50kpa带T的表)
总压力损失
≤250 Pa
最大指示值
99999.9998 m³
计数器最小读数
0.0002 m³
工作温度范围
-10℃~+40℃
符合标准
GB/T6968-2011 、CJ/T112-2008
- The product quality meets the requirements of GB/T6968-2011 Membrane Gas Meter, GB3836.1-2010 Electrical Equipment for Explosive Gas Environment Part 1: General Requirements, GB3836.4-2010 Electrical Equipment for Explosive Gas Environment Part 4: Essentially Safe "i". The explosion-proof mark is Ex IB II B T3 Gb, which is protected by the state. The explosion detection center is qualified and limited to the explosion-proof certificate. It contains the 1st and 2nd zones of IIA-IIB and the places of T1-T3 explosive gas mixture.
1, use alkaline batteries.
2, when replacing batteries, please do not mix old and new batteries or different types of batteries.