• The MTTM Series Turbine flowmeter is a high precision flowmeter, which designed and developed by ourselves on the basis of absorbing the advantages of imported products. The product integrates the functions of machinery, termperature and pressure correction, remote transmission, recharge,valve control into one assembly. The product is mainly used in gas metering for industrial and commercial users.The product is exquisite and beautiful in appearance, whose performance is leading position in the industry, with a variety of specification.

  • The product’s mechanical performance is stable. Range ratio can reach 1:20. 

    Intergrated Mechanica counting, temperature and pressure correction, remote transmission, recharge, valve control into one assembly. 

    The battary life can last more than 3 years

     and the memery can store data for 12 months ( a set of data per hour)

    The meter head can rotate freely and easy to reading data.

  • Specification

    Flow Range

    Flange OD

    Pressure Loss

    Flange Distance

    Length

    m3/h

    mm

    kPa

    mm

    mm

    MTTM-50A(Z)

    5~65

    DN50

    0.6

    150

    411

    MTTM-50B(Z)

    8~100

    0.9

    MTTM-50C(Z)

    10~160

    2.0

    MTTM-80A(Z)

    8~160

    DN80

    0.7

    240

    439

    MTTM-80B(Z)

    13~250

    1.2

    MTTM-80C(Z)

    20~400

    2.2

    MTTM-100A(Z)

    13~250

    DN100

    0.7

    300

    468

    MTTM-100B(Z)

    20~400

    1.0

    MTTM-100C(Z)

    32~650

    2.3

    MTTM-150A(Z)

    32·650

    DN150

    0.7

    450

    528

    MTTM-150B(Z)

    50~1000

    1.0

    MTTM-150C(Z)

    80~1600

    2.3

    MTTM-200A(Z)

    50~1000

    DN200

    0.7

    600

    595

    MTTM-200B(Z)

    80~1600

    0.9

    MTTM-200C(Z)

    130~2500

    1.7

    MTTM-250A(Z)

    80~1600

    DN250

    0.6

    750

    660

    MTTM-250B(Z)

    130~2500

    1.0

    MTTM-250C(Z)

    200~4000

    2.0

    MTTM-300A(Z)

    130~2500

    DN300

    0.7

    900

    722

    MTTM-300B(Z)

    200~4000

    1.0

    MTTM-300C(Z)

    320~6500

    2.0

    Remarks 1. Nominal pressur: PN1.6Mpa, Standard Pressure sensor 0.5Mpa, any special requirement from customer need to send new request when send orders.

    2. All products is according to the requirement of grade 1.5, 1.0.

    3. Smart roots flowmeter’s specification has the lettle “Z“and Mechanical flowmeter has no lettle"z"

  • 通经

    mm

    PN

    MPa

    A

    B

    H

    D

    K

    d

    n

    L

    智能

    机械

    双显

    DN25

    1.6

    200

    164

    318

    228

    387

    115

    85

    14

    4

    14

    2.5

    4.0

    DN50

     

    1.6

    200

    214

    344

    252

    404

    165

    125

    99

    4

    18

    2.5

    4.0

    DN80

    1.6

    240

    241

    374

    276

    418

    200

    160

    132

    8

    18

    2.5

    4.0

    DN100

    1.6

    300

    262

    393

    361

    493

    220

    180

    156

    8

    18

    2.5

    270

    400

    369

    501

    235

    190

    156

    8

    22

    4.0

    DN150

    1.6

    450

    313

    457

    426

    556

    285

    240

    211

    8

    22

    2.5

    321

    465

    434

    564

    300

    250

    211

    8

    26

    4.0

    DN200

     

    1.6

    600

    368

    501

    470

    600

    340

    295

    266

    12

    22

    2.5

    378

    511

    480

    610

    360

    310

    274

    12

    26

    4.0

    386

    519

    488

    618

    375

    320

    284

    12

    30

    DN250

    1.6

    750

    438

    572

    541

    671

    405

    355

    319

    12

    26

    2.5

    448

    582

    551

    681

    425

    370

    330

    12

    30

    4.0

    460

    594

    563

    693

    450

    385

    345

    12

    33

    DN300

    1.6

    900

    482

    627

    706

    839

    460

    410

    370

    12

    26

    2.5

    495

    640

    719

    849

    485

    430

    389

    16

    30

    4.0

    515

    655

    734

    864

    515

    450

    409

    16

    33

  • 1: Selection should be within the prescribed flow range to prevent over-speed operation, in order to obtain the desired accuracy and ensure normal service life. (Flowmeters can be damaged by over-speed operation due to pressure testing, purging of pipes or exhaust gas, and the operation of turbines in reverse flow)

    2: In order to prevent the pipeline and flowmeter from being damaged by the instantaneous airflow impact, the flowmeter should open the front valve slowly when it is put into operation, and gradually increase the flow rate so as to avoid damaging the turbine by the instantaneous airflow impact. Then slowly open the valve and run for 1 to 2 minutes at a small flow rate. After the flowmeter is in normal operation, all the valves are opened (opening time is not less than 15S). The valve should be slowly closed after closing the valve. Do not shut down suddenly.
    3: The number of times to add lubricating oil depends on the cleanliness of the temperament, usually once a month. The specific operation and lubricating oil can be seen in the oil cup label.
    4: When the flowmeter is running, it is not allowed to open the back cover or change the internal parameters, otherwise it will affect the normal operation of the flowmeter.
    5: If the output signal is 4mA-20mA current signal, in order to improve its accuracy, users should set the corresponding value of 20mA according to the actual maximum standard volume flow value.
    6: do not loosen the fixed parts of the flowmeter at will.
    7: After installation, air tightness test should be carried out on the pipeline to strictly check the air tightness of the pipeline. For auxiliary technical equipment equipped with pressure compensator, attention should be paid to the pressure range of the pressure testing equipment in order to avoid damaging the pressure measuring components.
    8: strictly prohibit the flow meter on-line welding pipe flange.
    9: there is no strong external magnetic field disturbance and strong mechanical vibration around the flowmeter.
    10: When the flowmeter is installed outdoors, it is suggested to add protective cover to avoid the influence of rainwater immersion and sunshine on the service life of the flowmeter.
    11: the flowmeter should be reliably grounded, but it must not be shared with the strong power system ground wire. When installing or overhauling the pipeline, the ground wire of the welding system shall not be overlapped with the flowmeter.
    12: In the course of use, users shall not change the connection mode of explosion-proof system and the interface of each lead arbitrarily.
    13: When installing, using and maintaining products, users must abide by the relevant provisions of Part 15 of the electrical equipment for explosive gas environment: electrical installation in dangerous places (except coal mines). When the product is used in the "0" zone, the power transformer supplying power to the safety grid shall comply with Article 8.1 of GB3836.4-2000.
    14: The product must match with the safety grid identified by the explosion-proof inspection organ to form the intrinsic safety explosion-proof system. The shielded cable is used to connect the cable, and the shielding layer is grounded in the safe place. The distribution parameters of the cable are within 0.2uF/0.3mH.
    15: installation and use requirements of intrinsically safe explosion-proof products
    The intrinsic safety explosion-proof products equipped with SMARC volume corrector must comply with the following requirements in addition to the precautions for the use of the above-mentioned Article 6.
    16: on-site installation and maintenance must turn off the external power before opening.
    17: the product shell has earthing terminals, users should be reliably grounded when using products.
    18: there should be no harmful gas to the aluminum alloy at the installation site.
    19: Maintenance and battery replacement must be carried out in a safe place. Maintenance can only be carried out when the presence of non-combustible gases is confirmed at the installation site.
    20: When using external power supply, it must be matched with the related equipment (safety grille) identified by the explosion-proof certification authority to form the intrinsic safety explosion-proof system before it can be used in the corresponding explosive dangerous places. The shielded cable is used to connect the cable, and the shielding layer is grounded in a safe place. The distribution parameters of the cable are controlled within 0.05uf/1mH.
    21: Safety grate must be installed in safe place, and its installation, use and maintenance must comply with the relevant provisions of the safety grate instructions.
    22: users are not allowed to change electrical components in their own products at will.
    23: When installing, using and maintaining products, users must abide by the relevant provisions of GB50058-92 "Code for Design of Electric Power Devices in Explosive and Fire Hazardous Environment" and "Code for Electrical Safety in Explosive Hazardous Places of the People's Republic of China".
    24: intrinsically safe hazardous areas below 1 zones for combustible gases of type II B class T4.